CyberResearch UCERB 24 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Sítě CyberResearch UCERB 24. CyberResearch UCERB 24 User`s manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 38
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Digital I/O
USER’S MANUAL
VER. 4 • MAY 2005
No part of this manual may be reproduced without permission
UCERB 24
USB Electromechanical Relay
Module - 24 SPDT (Form C)
Relays, with 24 Screw Terminals
®
CyberResearch
®
, Inc.
www.cyberresearch.com
25 Business Park Dr., Branford, CT 06405 USA
203-483-8815 (9am to 5pm EST) FAX: 203-483-9024
Zobrazit stránku 0
1 2 3 4 5 6 ... 37 38

Shrnutí obsahu

Strany 1 - UCERB 24

Digital I/O USER’S MANUAL VER. 4 • MAY 2005 No part of this manual may be reproduced without permission

Strany 2

Chapter 1 Introducing the UCERB 24Overview: UCERB 24 features This user's guide contains all of the information you need to connect the UCERB 24

Strany 3

UCERB 24 block diagram UCERB 24 functions are illustrated in the block diagram shown here. USB Microcontroller500 mAUSB 2.0compliantinterfacePowerRegu

Strany 4

Connecting a UCERB 24 to your computer is easy Installing a data acquisition device has never been easier.  The UCERB 24 relies upon the Microsoft

Strany 5 - CyberResearch, Inc. iii

Chapter 2 Installing the UCERB 24 What comes with your UCERB 24 shipment? The following items are shipped with the UCERB 24. Hardware The following i

Strany 6

Unpacking the UCERB 24 As with any electronic device, you should take care while handling to avoid damage from static electricity. Before removing the

Strany 7 - CyberResearch, Inc. v

Each DIP switch sets the configuration of one relay group. The DIP switch labeled A configures relays 1 to 8, the switch labeled B configures relays 9

Strany 8

The PWR LED illuminates green when 9 V power is supplied to the UCERB 24. If the voltage supply is less than 6.0 V or more than 12.5 V, the PWR LED do

Strany 9 - About this User’s Guide

Installing the software  Turn your computer on if it is not already running.  Log onto Windows with administrative privileges.  Make sure y

Strany 10 - Introducing the UCERB 24

1. Click on the OK button. The Microsoft .NET Framework 1.1 Setup dialog opens. 2. The button you click depends on whether or not you want to in

Strany 11 - Software features

Install the DAQ Software Whether or not you install the.NET Framework 1.1, the remaining dialogs are the same, starting with the Welcome… dialog.

Strany 13 - Installing the UCERB 24

5. Read the license agreement. If you agree with the terms, click on the I accept the terms of this license agreement option, and then click on the N

Strany 14 - Unpacking the UCERB 24

When the software is installed, the Setup Completed dialog opens. If VS .NET is not detected during installation If Visual Studio .NET is not de

Strany 15 - NON-INVERTINVERT

Chapter 3 Functional Details Internal components The UCERB 24 has the following internal components, as shown in Figure 3-1.  Two (2) USB connector

Strany 16

USB LED The USB LED indicates the communication status of the UCERB 24. It uses up to 5 mA of current and cannot be disabled. Ta explains the USB LED

Strany 17 - Installing the software

Pull-up/pull-down switch (S2) The Pull-up/pull-down switch (S2) sets the power-on state of each relay bank. By default, switch S2 is configured for pu

Strany 18

1. 2. 3. Connect the POWER OUT connector on the connected module to the POWER IN connector on the new module. This step is required only if you plan t

Strany 19 - Install the DAQ Software

The relay contacts associated that are with each relay location are listed in . Table 3-4Table 3-4. Relay locations and associated contacts R35, R36

Strany 20

Chapter 4 Specifications Typical for 25 °C unless otherwise specified. Specifications in italic text are guaranteed by design. Output specifications

Strany 21

Power Table 4-2. Power specifications Parameter Conditions Specification USB +5 V input voltage range 4.75 V min. to 5.25 V max. USB +5 V supply

Strany 22 - Functional Details

USB specifications Table 4-5. USB specifications USB "B" connector Input USB device type USB 2.0 (full-speed) Device compatibility USB 1.

Strany 24 - Screw terminals

Screw terminal pin out Table 4-10. Screw terminal pin out Pin Signal Name 1-NC Relay 1 Normally Closed contact 1-C Relay 1 Common contact 1-NO Rela

Strany 25 - Relay configuration

Pin Signal Name 22-NC Relay 22 Normally Closed contact 22-C Relay 22 Common contact 22-NO Relay 22 Normally Open contact 23-NC Relay 23 Normally C

Strany 26

UCERB 24 CyberResearch® Digital I/O 24 ©Co

Strany 27 - Specifications

CyberResearch® Digital I/O UCERB 24 CyberResearch, Inc. 25 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www

Strany 28 - External power output

UCERB 24 CyberResearch® Digital I/O 26 ©Copyright 2005 CyberResearch, Inc. Intentionally Blank

Strany 29 - 0 to 95% non-condensing

CyberResearch® Digital I/O UCERB 24 CyberResearch, Inc. 27 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www

Strany 30 - Screw terminal pin out

UCERB 24 CyberResearch® Digital I/O 28 ©Copyright 2005 CyberResearch, Inc. Intentionally Blank

Strany 32 - Digital I/O

CyberResearch, Inc.25 Business Park DriveBranford, CT 06405 USAP: (203) 483-8815; F: (203) 483-9024www.cyberresearch.com

Strany 34 - Intentionally Blank

CyberResearch® Digital I/O UCERB 24 CyberResearch, Inc. iii 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA ww

Strany 35 - Warranty Notice

UCERB 24 CyberResearch® Digital I/O iv ©Copyright 2005 CyberResearch, Inc. Intentionally Blank

Strany 36

CyberResearch® Digital I/O UCERB 24 CyberResearch, Inc. v 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.

Strany 37

UCERB 24 CyberResearch® Digital I/O vi ©Copyright 2005 CyberResearch, Inc.

Strany 38 - CyberResearch, Inc

Preface About this User’s Guide What you will learn from this user’s guide This user’s guide explains how to install, configure, and use the UCERB 24

Komentáře k této Příručce

Žádné komentáře